7.1. Main Unit
7.1.1. Vertical Airflow Direction Vane.
Airflow direction adjustment Up-and-Down.
The vertical airflow direction vane may
be positioned to deflect the air
upwards,downwards or straight on.
Use the air conditioner under the following conditions:
Operating temperature range.
Indoor side Outdoor side
D.B.T. W .B.T. D.B.T. W .B.T.
Cooling Maximum Temperature 32°C 23°C 43°C 26°C
Minimum Temperature 21°C 15°C 21°C 15°C
Heating Maximum Temperature 27°C ---- 21°C 15°C
Minimum Temperature 20°C ---- -5°C -6°C
7.1.2. Ventilation Lever.
W hen the slide lever is in the:
OPEN”position,the ventilation door is
opened to allow air,smoke and odors to
be expelled from the room.
CLOSE”position,the ventilation door is
closed and the air inside the room is
circulated and conditioned.
D.B.T.: DryBulb Temperature
W .B.T.: W et Bulb Temperature
Note: Humiditymayexceed 90% .
Continuous operation at humidity may create
condensation and result in water drops on the intake
and outlet vanes
7 Operating Instructions
7.1.3. Main Control Knob
7.1.4. Operation Conditions.