DIMENSIONS
(Units: mm)
With removable target mask attached
Streamlines color adjustment
in printing, even on substrates
with uorescent whitening agents
Density
Color
Illumination
Spectrodensitometer
FD
-
7/FD
-
5
3-in-1 next-generation measurement tool
Main specifi cations
Model FD-7 FD-5
Illumination/viewing system
45°a: 0°(annular illumination)
Conforms to CIE No. 15, ISO 7724/1, DIN5033 Teil 7, ASTM E 1164, and JIS Z 8722 Condition a for refl ectance measurements.
Spectral separation device Concave grating
Wavelength range
Spectral refl ectance: 380 to 730 nm; Spectral irradiance: 360 to 730
nm
Spectral refl ectance: 380 to 730 nm
Wavelength pitch 10 nm
Half bandwidth Approx. 10 nm
Measurement area Ø3.5mm
Light source LED
Measurement range Density: 0.0D to 2.5D; Refl ectance: 0 to 150%
Short-term repeatability
Density:
σ
0.01D
Colorimetric: Within
σΔ
E00 0.05 (When white plate is measured 30 times at 10-second intervals after white calibration has been performed)
Inter-instrument agreement
Within
Δ
E00 0.3 (Average of 12 BCRA Series II color tiles compared to values measured with a master body under Konica Minolta standard
conditions)
Measurement time Approx. 1.4 s (single-point refl ectance measurement)
Displayed values
Colorimetric values, color-difference values, density values,
density-difference values, dot area ratio, dot gain, PASS/FAIL
judgment, illuminance, correlated color temperature
Colorimetric values, color-difference values, density values, density-
difference values, dot area ratio, dot gain, PASS/FAIL judgment
Measurement conditions
Corresponding to ISO 13655 Measurement Conditions M0 (CIE Illuminant A), M1 (CIE Illuminant D50), and M2 (illumination with UV-cut
fi lter); User-defi ned illuminant
Illuminants A, C, D50, D65, ID50, ID65, F2, F6, F7, F8, F9, F10, F11, F12, User-defi ned illuminant
Observers 2° Standard Observer, 10° Standard Observer
Color spaces L
a
b
, L
C
h, Hunter Lab, Yxy, XYZ and color-difference in these color spaces
Color-difference equations
Δ
E
ab (CIE 1976),
Δ
E
94 (CIE 1994),
Δ
E00 (CIE 2000),
Δ
E (Hunter), CMC (l:c)
Indexes WI (ASTM E313-96); Tint (ASTM E313-96); ISO Brightness (ISO 2470-1); D65 Brightness (ISO 2470-2); Fluorescence index
Density ISO Status T, ISO Status E, ISO Status A, ISO Status I; DIN16536
Storable data Colorimetric target data: 30 data; Density target data: 30 data
Display language English, French, German, Spanish, Japanese, Chinese (Simplifi ed)
Scanning measurements
Scanning measurement of a color chart can be performed. N/A
Interface USB 2.0
Output data
Displayed values; Spectral reflectance data; Spectral irradiance
data
Displayed values
Power Rechargeable internal lithium-ion battery (Number of measurements per charge: Approx. 2,000 when new); AC adapter; USB bus power
Dimensions (W × D × H) 70 × 165 × 83mm (Body only); 90 × 172 × 84mm (With target mask attached)
Weight Approx. 350g (Body only); Approx. 430g (With target mask attached)
Operating temperature/
humidity range
10 to 35°C, 30 to 85% relative humidity with no condensation
Storage temperature/humidity
range
0 to 45°C, 0 to 85% relative humidity with no condensation
1 Illumination for wavelengths under 400nm is unidirectional.
2 Available when using PC software.