Emerson enrutador de red Network Router Manual

Manuales PDF
110 Páginas Español

Emerson enrutador de red Network Router
Installation and Use Manual 21
Installation and Setup
ProLink II Setup Transmitter StartupUsing ProLink IIBefore You Begin
3. For long-distance communication, or if noise from an external source interferes with the
signal, install 120-Ω, 1/2-watt resistors (R1) across terminals of both end devices.
Note: The Modbus protocol allows only one Modbus master to be active on the network at any given
time. If you are connecting through a network, ensure that no other Modbus master devices are
currently active.
Figure 2-7 Modbus/RS-485 connection to RS-485 multidrop network
Table 2-10 Lead-to-terminal assignments – Method 6
Transmitter
Terminals
RS-485/A RS-485/B
Model 1500/2500 33 34
Model 1700/2700 AN 5 6
Series 3000 panel-mount with screw-type connectors a32 c32
Series 3000 panel-mount with I/O cables 25 24
Series 3000 rack-mount a32 c32
Series 3000 field-mount 12 11
RFT9712 21 22
RFT9739 field-mount 27 26
RFT9739 rack-mount Z22 D22
DCS or
PLC
R1
See Step 3
BLACK
BOX
25-pin to 9-pin serial port adapter
(if necessary) (not shown)
RS-485 terminals
See Step 2
Tra n sm itt er
Tabla de Contenidos